Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Pulm Med ; 19(1): 219, 2019 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-31752776

RESUMO

BACKGROUND: Malignant central airway obstruction (CAO) occurs in approximately 20-30% of patients with lung cancer and is associated with debilitating symptoms and poor prognosis. Multimodality therapeutic bronchoscopy can relieve malignant CAO, though carries risk. Evidence to guide clinicians regarding which patients may benefit from such interventions is sparse. We aimed to assess the clinical and radiographic predictors associated with therapeutic bronchoscopy success in relieving malignant CAO. METHODS: We reviewed all cases of therapeutic bronchoscopy performed for malignant CAO at our institution from January 2010-February 2017. Therapeutic bronchoscopy success was defined as establishing airway patency of > 50%. Patient demographics and baseline characteristics, oncology history, degree of airway obstruction, procedural interventions, and complications were compared between successful and unsuccessful groups. Univariate and multivariate logistic regression identified the significant clinical and radiographic predictors for therapeutic success. The corresponding simple and conditional odds ratio were calculated. A time-to-event analysis with Kaplan-Meier plots was performed to estimate overall survival. RESULTS: During the study period, 301 therapeutic bronchoscopies were performed; 44 (14.6%) were considered unsuccessful. Factors associated with success included never vs current smoking status (OR 5.36, 95% CI:1.45-19.74, p = 0.010), patent distal airway on CT imaging (OR 15.11, 95% CI:2.98-45.83, p < 0.0001) and patent distal airway visualized during bronchoscopy (OR 10.77, 95% CI:3.63-31.95, p < 0.001) in univariate analysis. Along with patent distal airway on CT imaging, increased time from radiographic finding to therapeutic bronchoscopy was associated with lower odds of success in multivariate analysis (OR 0.96, 95% CI:0.92-1.00, p = 0.048). Median survival was longer in the successful group (10.2 months, 95% CI:4.8-20.2) compared to the unsuccessful group (6.1 months, 95% CI:2.1-10.8, log rank p = 0.015). CONCLUSIONS: Predictors associated with successful therapeutic bronchoscopy for malignant CAO include distal patent airway visualized on CT scan and during bronchoscopy. Odds of success are higher in non-smokers, and with decreased time from radiographic finding of CAO to intervention.


Assuntos
Obstrução das Vias Respiratórias/cirurgia , Broncoscopia , Qualidade de Vida , Neoplasias do Sistema Respiratório/cirurgia , Idoso , Obstrução das Vias Respiratórias/etiologia , Obstrução das Vias Respiratórias/mortalidade , Dispneia/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Neoplasias do Sistema Respiratório/complicações , Neoplasias do Sistema Respiratório/mortalidade , Estudos Retrospectivos , Análise de Sobrevida , Tomografia Computadorizada por Raios X , Resultado do Tratamento
2.
Lancet Respir Med ; 7(5): 447-455, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30772283

RESUMO

BACKGROUND: In patients with non-expandable lung, removal of pleural fluid can result in excessively negative pleural pressure, which is associated with chest discomfort, pneumothorax, and re-expansion pulmonary oedema. Pleural manometry is widely used to safeguard against pressure-related complications during thoracentesis despite little evidence to support the approach. We investigated whether monitoring of pleural pressure with manometry during thoracentesis could protect against complications compared with assessment of symptoms alone. METHODS: We did a prospective randomised single-blind trial involving patients with large pleural effusions at two academic medical centres in, Nashville, TN, and Baltimore, MD, USA. Eligible patients were adults with free-flowing effusions estimated to be at least 0·5 L who could remain seated throughout the procedure. Patients were randomly assigned 1:1 to receive thoracentesis guided by symptoms only (control) or by symptoms plus manometry at timepoints based on volume drained. The randomisation schedule was computer generated, used permuted blocks of four and six, and was stratified by participating institution. Patients, who were masked to study-group assignment, were asked to rate chest discomfort on 100 mm visual analogue scales before, during, and after drainage. In both groups drainage was discontinued before complete evacuation of pleural fluid if patients developed persistent chest discomfort, intractable cough, or other complications. In the manometry group, an additional criterion for stopping was if end-expiratory pleural pressure was lower than -20 cm H2O or declined by more than 10 cm H2O between two measurements to a value less than or equal to -10 cm H2O. The primary outcome was overall chest discomfort from before the start to after the procedure measured by patients 5 min after the end of drainage. Analysis was by modified intention to treat (ie, included all patients with any procedure or outcome data). This trial is registered with ClinicalTrials.gov, number NCT02677883. FINDINGS: Between March 4, 2016, and Sept 8, 2017, 191 patients were screened, of whom 128 were randomly assigned treatment and 124 were included in the final analysis (62 in each group). Four patients were excluded because of manometer malfunction (n=2), inability to access effusion due to pleural tumour burden (n=1), and inability to remain seated (n=1). Groups did not differ for the primary outcome (mean difference in chest discomfort score 2·4 mm, 95% CI -5·7 to 10·5, p=0·56). Six (10%) of 62 patients in the control group had asymptomatic pneumothorax ex vacuo compared with none in the manometry group (p=0·01). No serious complications occurred in either group. INTERPRETATION: Measurement of pleural pressure by manometry during large-volume thoracentesis does not alter procedure-related chest discomfort. Our findings do not support the routine use of this approach. FUNDING: Centurion Medical Products.


Assuntos
Derrame Pleural/terapia , Pneumotórax/prevenção & controle , Edema Pulmonar/prevenção & controle , Toracentese/métodos , Idoso , Feminino , Humanos , Masculino , Manometria/métodos , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...